7.6

Linking of reading feeders

When two feeders are linked and used as
reading feeders, you need to use sequence
check for a good level of security. When this is
done make sure that the feeders are (re)filled in
the correct order (feeder 1 first) to prevent
sequence errors.
In addition to this make sure that complete sets
are loaded in every reading feeder. Should it
inadvertently happen that a document set is
divided between the two feeders, the system will
display error (4: - 9:) 15 which means that the
set is incomplete.
7.7

Removed/reselecting links

When editing a "reading" job or when switching
on the reading, the system will check the
configuration for links which are not possible
with the selected reading code. In that case all
links in this job will be removed. Necessary links
have to be selected again. It is advised to check
in the document settings menu if the required
links are still present.