Christie Roadster S+12K User Manual page 93

Christie roadster s+12k; roadster hd12k; roadster s+16k; roadster hd18k; roadster s+20k; mirage hd12; mirage s+14k; mirage hd18 data/video projector
Hide thumbs Also See for Roadster S+12K:
Table of Contents

Advertisement

System Configuration 
DIAGNOSTICS / CALIBRATION
Roadster & Mirage S+/HD User Manual
020-100002-04 Rev. 1 (12-2008)
NOTES: 1) See System Configuration – Diagnostics/Calibration, ILS Calibration
for further details about calibration. 2) ILS
be retained between power cycles.
Test Pattern
Choose the desired internal test
pattern to display, or select OFF
to turn off a test pattern.
Alternatively, use the
Test
for cycling through test patterns.
NOTE: There is a center line
(both horizontal and vertical) in
the Edge Blending test pattern.
The intersection of these lines is
the true center of the projector's
display area.
Test Pattern Grey Level
Set the desired level of grey for displaying in the full gray field test pattern.
Freeze Image
Enter a check mark to freeze (stop) an image on a single frame. This diagnostic tool
is useful if you need to examine in detail a still version of an incoming image that
cannot be "frozen" at the source. For example, in moving images it is sometimes
difficult to observe artifacts such as external de-interlacing/resizing and signal noise.
Remove the checkmark to return back to normal.
Color Enable
Select which color or colors you want to see. This is useful while working with color
temperature, input levels or other special setup parameters. Colors can also be
enabled or disabled by entering the corresponding function code listed on the back of
the standard remote keypad.
Odd Pixel Adjustment
NOTES: 1) Factory-set and rarely required by user. 2) Source must be >90 MHz.
When using certain RGB sources, you may need to adjust the normal gain or offset of
odd pixels in relation to even pixels. This will smooth out very narrow (1-pixel wide)
"checks" or vertical stripes that indicate adjacent "on" and "off" pixels. Using the
Level Detector simplifies this process (see Figure 3.25):
1. Use an external analog native-sized continuous grayscale test pattern with at least
256-levels.
2. Turn "Level Detector" on.
3. Set "Level Value" to ~200. The image should now be black-and-white (or black-
and-one color, if you use "Color Enable" function).
4. Adjust offset. Half of the pixels will move, the other half will not.
5. Adjust until the two transition regions overlap. The stripe of noise will be
minimized, defined by the value in the slidebar.
6. Set "Level Value" to ~800. The image should now be black-and-white.
control is a preference setting and will
1.
2.
3.
key
4.
5.
Odd Pixel Adjustment
6.
7.
8.
9.
0.
Aspect Ratio Overlay
LiteLOC Calibration
Automatic ILS Lens Calibration
Operation
Diagnostics and Calibration
Test Pattern
Grid
Grey Level
512
Freeze Image
Color Enable
White
Reserved
Peak Detector
Level Detector
Level Value
512
Calibrate LiteLOC
ILS Calibration
Full Calibration
3-51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents