Input Panel
The input panel wires the projector to inputs (sources) and controllers such as PCs.
COMPOSITE/S-VIDEO INPUT -
signal from devices such as VCRs.
Accepts RGB and sync signals from devices such as computers, as
RGB INPUT -
well as composite video, S-Video or YPbPr component signals.
RS232 SERIAL INTERFACE (WITH LOOP THROUGH) -
projectors to be remotely controlled by a computer or controller,
RS422 INTERFACE -
an RS422 compatible computer or controller (such as the Two-Way Controller
accessory).
AC Power Input and Monitoring
AC LINE CORD INPUT -
recommended by Christie. See Section 5. Before unplugging, wait until the main blower
turns off or the LCD status reads Power Off.
Model
Roadster S+12K/HD12K
Mirage HD12
Roadster S+16K
Mirage S+14K
Mirage HD18
Roadster S+20K/HD18K
Do not attempt operation if the AC supply is not within the
specified voltage and power range. Use the specified line cord.
Displays incoming voltage level reaching the projector.
VOLTMETER -
SWITCH/BREAKER -
power switch for the ballast 2) It protects against excessive AC conditions (15A
or more for Roadster S+12K/HD12K and Mirage HD12, 20A or more for
Roadster S+16K/Mirage S+14K, and 25A or more for Roadster S+
20K/HD18K/Mirage HD11/Mirage HD18). If the projector is faulty or excessive
AC is detected, the breaker will "trip" to OFF in order to prevent damage. Try
moving the breaker ON again - if the breaker continues to trip OFF, this indicates
a major fault and the AC problem must be resolved. Possible causes might
include shorts, damage to lamp cables, or excessive AC.
NOTE: This switch powers only the ballast—it does not power up the projector
or start the lamp. You must press
Two Status Displays:
TWO-DIGIT STATUS/ERROR CODE WINDOW -
display is adjacent to the built-in keypad. During normal operation, the "Power"
light is steady yellow and indicates "on". When the status of the projector
changes, the LED displays a two-digit code number representing the projector's
new status. In addition to the numeric readout, there are two decimal points in the
display: the right decimal point flashes when the projector receives a command,
and the left point flashes when the projector sends a command.
Accepts a composite video, DVI and S-Video
Allows one or more projectors to be remotely controlled by
Use the AC supply specified, and always use the line cord
AC Power Specifications
200-240 VAC, 50-60 Hz, max. 12 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 12 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 16 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 16 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 24 amps @ 200VAC
200-240 VAC, 50-60 Hz, max. 24 amps @ 200VAC
WARNING
The breaker on the rear panel serves two purposes: 1) It is a
on the keypad.