Christie Roadster S+12K User Manual page 34

Christie roadster s+12k; roadster hd12k; roadster s+16k; roadster hd18k; roadster s+20k; mirage hd12; mirage s+14k; mirage hd18 data/video projector
Hide thumbs Also See for Roadster S+12K:
Table of Contents

Advertisement

Installation & Setup
2-24
Figure 2.32. RS232 Serial Link Loop-Through at First Projector
: To control multiple projectors with a computer/controller having
MIXED NETWORK
an RS422 interface, first set them all to the same baud rate as your RS422 controller.
NOTE: You must enable this combination of RS422 and RS232 in the
Communications menu. Set the "Network Routing" option to "RS232 and RS422
Joined". See Section 3 for details.
Chain the projectors together by connecting an
(already connected to the computer/controller through the
port on the next projector in the chain. Continue connecting projectors in this manner
until you've reached the last projector in the chain, so that only the last projector has
one unused
port. See Figure 2.33.
RS232
Note that communication parameters such as baud rate must be set to match the
particular controlling device before connecting as a network—refer to the
documentation that came with your controlling device in order to determine the
proper baud rate. See 3.7, Adjusting System Parameters and Advanced Controls if you
need help changing the projector baud rate. In addition, set the Network Routing to
"RS232 and RS422 Joined" if you want to reach all projectors.
NOTES: 1) To avoid damage, connect only properly wired serial communication
cables. See Appendix C for details. 2) It is recommended that each RS232
communication cable be no more than 25 feet in length. Use high quality cables.
RS232
Figure 2.33. Mixed Serial Network
port of the first projector
port) to an
RS422
Roadster & Mirage S+/HD User Manual
020-100002-04 Rev. 1 (12-2008)
RS232

Hide quick links:

Advertisement

Table of Contents
loading