Technical Data
4.2

Mechanical data

Visual displays
Controls
DC isolator switch
DC connections
Ambient temperature
Temperature monitoring
Max. humidity
Maximum installation elevation
[m above sea level]
Cooling
Protection class
Degree of contamination
Noise emission
Housing
H x W x D [mm]
Total weight [kg]
Table 3:
Mechanical data
Operating Instructions for Powador 2002-6002_EN
2002
3002
LEDs: PV generator (green), supply (green), fault (red)
2 keys for operating display
Integrated DC isolator switch with rotary switch
6 (2 x 3) MC-4 compatible solar plug connections
-20 °C to +60 °C (Powador 2002 / 3002)
-25 °C to +60 °C (Powador 4202 / 6002)
(> +40 °C Power derating at high ambient temperatures)
> 75 °C
> 85 °C
Free convection (no
IP54 according to EN 60529
< 35 dB (noiseless)
Aluminium wall-mounted housing
450 x 340 x
500 x 340 x
200
200
14.5
20
4202
5002
LCD (2 x 16 characters)
> 70 °C (temperature-dep.
power matching)
> 80 °C (disconnection from the grid)
95% (non-condensing)
2 000
fan)
2
< 45 dB (fan operation)
600 x 340 x
600 x 340 x
240
240
26
28
6002
EN
Fan
600 x 340 x 240
28