Configuration and Operation
Coun-
try-spec.
Settings
EN
EN
All countries
All countries
Page 34
Menu
Display/
level
setting
Temperature inside
1
1
2
3
unit
1
1
2
3
Yield meter
1
1
2
3
Yield today
1
1
2
3
Total yield
1
1
2
3
CO2 savings
Operating hours
1
1
2
3
counter
Operating hours
1
2
1
3
today meter
Operating hours
1
1
2
3
total meter
1
1
2
3
Date/Time
Displaying
1
1
2
3
grid error
"Confi guration
1
2
2
3
mode" menu
1
2
2
3
Software version
Confi guration
1
2
2
3
version
1
2
2
3
Serial no.
Country and grid-
1
2
2
3
type display
Language
1
2
2
3
Clear grid-feed
1
2
2
3
meter
Action in this menu/meaning
Displays the temperature of the heat sink in °C.
If the unit overheats, power is automatically reduced until
it is shut down completely.
Shows the total yield back to the last reset.
Press "2" to reset the yield meter.
Displays the cumulative yield for the current day.
Displays the previous yield.
Yield meter, "Yield today" and "Total yield" can be reset in
menu level "2" "Feed-in meter".
Displays the calculated CO
2
Shows the total operating time since the last reset.
Press "2" to reset the yield meter.
Displays the duration of operation on the current day.
Displays the total operating time.
With an additional PCB installed (real-time module RTC),
displays the current time and the date.
The fi ve most recent grid errors in last 1000 operating
hours are displayed.
 If "Yes" is selected, the corresponding fault messages
are displayed. Navigate through the fault messages
with the navigation button.
 After displaying the grid errors, the device runs
through the menu level and begins when key "1" is
pressed again with the display of the unit name.
 Press keys "1" and "2" to run through the following
menu level "2".
Displays the installed software version.
Displays the installed confi guration version.
Displays the serial number of the inverter.
Displays the selected country setting and grid type.
 Select the desired menu language.
Allows the grid-feed meter to be cleared.
("Yield" meter and "Operating hours" meter)
 If "yes" is selected the password is requested.
 Setting required password number "2"
If the code number is valid, the grid-feed meter is cleared
and a confi rmation is displayed with "Grid meter cleared!".
Operating Instructions for Powador 2002-6002_EN
savings (in kg).