Technical Data
4.2

Mechanical data

EN
EN
Visual displays
Controls
DC isolator switch
Interfaces
Fault signal relay
AC connections:
PCB terminal
AC connections:
Cable connection
DC connections
Ambient temperature
range [°C]
Humidity range (non-con-
densing) [%]
Maximum installation ele-
vation [m above sea level]
Temperature monitoring
Cooling
Protection rating according
to EN 60529
Degree of contamination
Noise emission [dB(A)]
Housing
H x W x D [mm]
Total weight [kg]
Table 3:
Mechanical data
Page 14
3200
4200
LEDs: PV generator (green), supply (green), fault (red)
Integrated DC isolator switch with rotary switch
Potential-free NO contact max. 30 V / 3 A
inside the unit (max. cross section: 10 mm²)
Cable connection via M32 cable fitting
Cable connection via M16 cable fitting
500 x 340 x
550 x 340 x
200
200
19
21
4400
5300
LCD (2 x 16 characters),
2 keys for operating display
RS232, RS485, S0
-20 ... +60
0 ... 95
2 000
Yes
Free convection (no fan)
IP54
2
< 35 / noiseless
Cast aluminium
550 x 340 x
550 x 340 x
220
220
21
26
Operating Instructions for Powador 3200-6600_EN
5500
6600
600 x 340 x
600 x 340 x
220
220
28
30