Technical Data
4.2

Mechanical data

EN
EN
Product name: KACO blueplanet
Display
Controls
Interfaces
Fault signal relay
AC connections
DC connections
Ethernet connection: Cable connection
Ambient temperature range [°C]
Humidity range (non-condensing) [%]
Maximum installation elevation [m above sea level]
Temperature monitoring
Cooling (free convection (K)/fan (L))
Protection rating according to EN 60529
Degree of contamination
Noise emission [dB(A)]
DC isolator switch
Housing
H x W x D [mm]
Total weight [kg]
CE conformity
Table 3:
Mechanical data
* The DC starting voltage can be set in the menu if needed.
4.3

Identification

Identifying the unit
You will find the name plate with product-specific data for service and
other requirements specific to installation on the right side panel of
the inverter. This data includes:
Product name
Part no.
Serial no.
Date of manufacture
Technical Data
Disposal information
Certification marking, CE marking.
Page 12
5.0-10.0 TL3
Graphical LCD, 3 LEDs
4-way button, 2 buttons
2 x Ethernet, USB, RS485, error relay
4 x digital inputs (optional)
Potential-free NO contact 30 V / 1 A
5-pole connection plug
4 (2 x 2) SUNCLIX connector
Cable connection via M25 cable fitting
-25 ... +60, power derating from +40
100
3000
Yes
L
IP65
2
<53
Built-in
Plastic (ASA/PC), aluminium
approx. 522 x 363 x 246
30
Yes
KACO blueplanet 7.5 TL3 M2 WM OD IIG0
Part number
Serial number 00000000000010005 Year Q2 / 16
KACO new energy
Carl-Zeiss-Straße 1
74172 Neckarsulm
Made in Germany
Vmax PV / lsc PV (max) / Inom PV
Input
V-MPP at Pnom / V- range
Nominal voltage
Output
Voltage range continuous operation
Current (maximum continuous)
Frequency range
Snom at 400 V /230 V Unom
Output
Power
Reactive power
cos phi
Environ-
Temperature range
ment
Protection class / Ingress protection
non
ARC fault circuit protection
Interface protection according to country
specific requirements, details see manual
No galvanic separation
Figure 4: Name plate
KACO Operating Instructions blueplanet 5.0 TL3 - 10.0 TL3
1001203
1000 Vdc /2x 16 A /2x 11 A
350 V - 800 V / 200 V - 800 V
400 V / 230 V (3/N/PE)
3 x 180 Vac - 277 Vac
3 x 11,45 A
45 Hz - 65 Hz
7500 VA
0-95 % Snom 1 - 0,3 ind/cap
-25°C...+60°C/-13°F...+140°F
I / IP65
4004945