4.2

Mechanical data

Display
Controls
Interfaces
Fault signal relay
AC connection (version, type, feed-through cross
section, cable cross section)
DC connection (version, type, feed-through cross
section, cable cross section)
Connection interfaces (type, feed-through cross
section)
Temperature monitoring
Cooling (free convection (K)/fan (L))
Degree of contamination PD
Noise emission [dB(A)]
DC isolator switch
Housing
H x W x D [mm]
Total weight [kg]
CE conformity
Table 2:
Mechanical data
* With a supply voltage of 240 V or higher the lower MPP voltage is increasing accordingly.
4.3

Environmental conditions

Product name: KACO blueplanet
29 TL3 M1 WM OD xxxx
Last 4 characters of product name/item number
Distance from coast
Ambient temperature range [°C]
Humidity range (non-condensing) [%]
Maximum installation elevation (m above mean
sea level)
Protection rating according to EN 60529
Table 3:
Environmental conditions
* For installation in aggressive environmental conditions (e.g. possibility of corrosion), you must contact the KACO
Sales team (pv-projects@kaco-newenergy.de).
Operating Instructions KACO blueplanet 29.0TL3
Graphical LCD, 3 LEDs
4-way button, 2 buttons
2x Ethernet, USB, RS485
optional via additional module: 4-DI
Potential-free NO contact, max. 30 V/1 A DC
S, M and XL; connection via screw terminals,
95 mm², cable connection via M63 cable fitting
S, M: Connection with cable lug, 95 mm², cable connection
via cable fitting M32
XL: Connection via 6x DC plug connectors, 2.5 - 6 mm², -
Network: Ethernet cable, cable connection via cable fitting
M25, standard
RS485: 2-wire, cable connection via cable fitting M16 max.
1.5 mm
Built-in
Aluminium
760 x 500 x 425
73(XL version) 71(M version) 69 (S-Version)
II4S
II4M
1001724 /
> 2000 m
-20 ... +60 Power reduction above +50
100
3000 (Power reduction above 2000)
IP65 (tested according to DIN EN 60068-2-52)
Yes
L
2
61
Yes
II4X
1001663 /
1001664
EN