Mechanical Data - Kaco Powador 30.0 TL3 M/X Operating Instructions Manual

Table of Contents

Advertisement

Technical Data
4.2

Mechanical data

EN
EN
Display
Controls
Interfaces
Fault signal relay
AC connection terminals
AC cable connection
DC connection terminals (M variant)
DC connection terminals (XL variant)
Connections for DC cable connection
Connection for Ethernet cable connection
Ambient temperature range [°C]
Maximum installation elevation (meter
above mean sea level)
Temperature monitoring
Cooling (free convection (K)/fan (L))
Protection rating according to EN 60529
Degree of contamination
DC isolator switch
Housing
H x W x D [mm]
Total weight [kg]
Table 3:
Mechanical data
Page 12
30.0-72.0 TL3
Graphical LCD, 3 LEDs
4-way button, 2 buttons
Ethernet, USB, RS485, S0, Digital output "Inverter off"
Potential-free NO contact, max. 30 V DC / 1 A
Screw terminals inside the unit
min. cross section: 16 mm² rigid/flexible
max. cross-section: 50 mm² rigid/flexible
Via M50 cable fitting
Screw terminals on top hat rail inside the unit
min. cross section: 6 mm² rigid/flexible
max. cross-section: 35 mm² rigid/flexible
Screw terminals on top hat rail inside the unit
min. cross section: 2.5 mm² rigid/flexible
max. cross-section: 10 mm² rigid/flexible
30.0 - 40.0 TL3: via 6 M32 cable fittings
60.0 - 72.0 TL3: via 6 M40 cable fittings
via M25 cable fitting
-20 ... 60
2,000
Yes
L
IP54
PD2
Built-in
Steel plating
1360 x 840 x 355
151 (30.0-48.0 TL3), 173 (60.0-72.0 TL3)
Operating Instructions for Powador 30.0-72.0 TL3_EN