Te ch nic al D at a
4.2
Mechanical data
Display
Controls
Interfaces
Fault signal relay
AC connection terminals
AC cable connection
DC connection terminals (M variant)
DC connection terminals (XL variant)
Connections for DC cable connection
Connection for Ethernet cable
connection
Ambient temperature range [°C]
Maximum installation elevation (m
above mean sea level)
Temperature monitoring
Cooling (free convection (K)/fan (L))
Protection rating according to EN 60529
Degree of contamination
DC isolator switch
Housing
H x W x D [mm]
Total weight [kg]
Table 3:
Mechanical data
4.3
Software
The software of the inverter uses the MD5 Message Digest algorithm of RSA Data Security, Inc.
Page 12
30.0-72.0 TL3
Graphical LCD, 3 LEDs
4-way button, 2 buttons
Ethernet, USB, RS485, S0, Digital output "Inverter off"
Potential-free NO contact, max. 30 V DC/1A or 230 V AC/1 A
Screw terminals inside the unit
min. cross section: 16 mm² rigid/flexible
max. cross-section: 50 mm² rigid/flexible
Cable connection via M50 cable fitting
Screw terminals on top hat rail inside the unit
min. cross section: 6 mm² rigid/flexible
max. cross-section: 35 mm² rigid/flexible
Screw terminals on top hat rail inside the unit
min. cross section: 2.5 mm² rigid/flexible
max. cross-section: 10 mm² rigid/flexible
Cable connection via 6 M40 cable fittings
Cable connection via M25 cable fitting
–20 ... 60
Steel plating
1360 x 840 x 355
151 (30.0-48.0 TL3), 173 (60.0-72.0 TL3)
2000
yes
L
IP 54
PD2
Built-in
Operating Instructions Powador 30.0-72.0 TL3_EN