Promise Technology VTRAK E310f Product Manual page 278

External disk array subsystem
Hide thumbs Also See for VTRAK E310f:
Table of Contents

Advertisement

VTrak E-Class Product Manual
Reported Event
Disk array settings have
been changed
Drive Interface Controller
Drive-interface controller
found
Drive-interface controller
is NOT found
Drive-interface
diagnostics has passed
Drive-interface
diagnostics has failed
Drive-interface controller
has generated a general/
data parity error.
Enclosure
Enclosure temperature is
above the threshold/
warning threshold
Enclosure temperature is
above the critical
threshold
Enclosure temperature is
within the normal range
Event Log
Event logging is enabled
Event logging is disabled Event logging has been disabled.
Event log buffer is cleared
in RAM
Event log buffer is cleared
in NVRAM
Event log buffer is cleared
in MDD
The user successfully logical drive settings. See
page 120.
Normal.
Restart the VTrak. See page 207. If this message
appears repeatedly, contact Technical Support. See
page 293.
Normal.
Restart the VTrak. See page 207. If this message
appears repeatedly, contact Technical Support. See
page 293.
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support. See
page 293.
The VTrak is overheating. Check for airflow around
and through the VTrak, and verify that all fans are
working. Replace fans as needed.
The VTrak is seriously overheating. Check for airflow
around and through the VTrak, and verify that all fans
are working. Replace fans as needed.
Normal.
Event logging has been successfully enabled.
The event log was cleared.
The non-volatile RAM event log was cleared.
The MDD (disk drive) event log was cleared.
264
Corrective Action