Toshiba e-STUDIO 600 User Manual page 134

Multinational digital systems
Hide thumbs Also See for e-STUDIO 600:
Table of Contents

Advertisement

7 TopAccess Administrator Mode
- Disable — Select this to disable SMB.
- Disable Print Share — Select this to enable the file sharing service using SMB, but dis-
able SMB printing.
- Disable File Share — Select this to enable SMB printing, but disable the file sharing ser-
vice using SMB.
2) Enable IPv6
Select whether the IPv6 protocol is enabled or disabled.
- Enable — Select this to enable IPv6.
- Disable — Select this to disable IPv6.
3) NetBIOS Name
Enter the NetBIOS name of this equipment. The equipment uses "MFP-<NIC Serial Num-
ber>" as the default NetBIOS name.
You can enter only alphanumeric characters and "-" (hyphenation) for NetBIOS name. If you
use any other characters, a warning message will be displayed.
4) Logon
Enter the workgroup or domain that this equipment joins.
- Workgroup — Select this and enter the workgroup name when the equipment will logon
in the workgroup. All client computers can access this equipment without a user name
and password.
- Domain — Select this and enter the domain name when the equipment will logon in the
domain. Any client computers which are not a member of the domain will need a valid
user name and password to access this equipment. Use this for a more secure access
to this equipment.
When the "Obtain a Domain Name automatically" option is enabled in the TCP/IP settings,
the domain name can be obtained using the DHCP server.
P.123 "Setting up the TCP/IP"
You can enter only alphanumeric characters and symbols except following characters for
Workgroup.
; : " < > * + = \ | ? ,
If you use any other characters, a warning message will be displayed.
5) Primary Domain Controller
Specify the server name or IP address of the primary domain controller when this equipment
will logon the domain network.
6) Backup Domain Controller
Specify the server name or IP address of the backup domain controller when this equipment
will logon the domain network, if required. If the Primary Domain Controller is unavailable,
the Backup Domain Controller will be used to logon.
If the wrong primary or backup domain controller is specified, the NIC INITIALIZING mes-
sage will be displayed for 5 to 10 minutes while this equipment searches for the primary or
backup domain controller. In that case, correct the primary or backup domain controller set-
ting after the NIC INITIALIZING message disappears.
134
Setting up from TopAccess

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 520E-studio 720E-studio 850

Table of Contents