Desk Transport Motor Trouble; Lcc Communication Trouble; Lcc Transport Motor Trouble; Lcc 24V Power Abnormality - Sharp MX-2300 G Service Manual

Digital full color multifunctional system
Hide thumbs Also See for MX-2300 G:
Table of Contents

Advertisement

U6-10

Desk transport motor trouble

Trouble content
Desk transport motor operation trouble
Section
PCU
Case 1
Cause
Motor lock, motor RPM abnormality, overcurent to the
motor, console finisher control PWB trouble
Check
Use SIM 4-3 to check the operation of the desk
and
transport motor.
remedy
U6-20

LCC communication trouble

Trouble content
LCC communication error. Communication line test
error after turning ON the power or canceling the
exclusive simulation. LCC and machine model codes
discrepancy error
Section
PCU
Case 1
Cause
Connector and harness connection trouble or
disconnection, LCC control PWB trouble, control PWB
(PCU) trouble, malfunction due to electrical noises
Check
Turn OFF/ON the power to cancel the trouble. Check
and
the connector and the harness of the communication
remedy
line.
U6-21

LCC transport motor trouble

Trouble content
• The encoder input value is not changed in 0.06sec
after turning on the motor.
• The encoder input value is changed after a certain
time from turning OFF the motor. (After 5sec, count
is made for 0.1sec to get 100 or more count.)
Section
PCU
Case 1
Cause
Motor lock, motor RPM abnormality, an overcurrent to
the motor, LCC control PWB trouble
Check
Use SIM4-3 to check the operation of the transport
and
motor.
remedy
U6-22

LCC 24V power abnormality

Trouble content
DC24V power is not supplied to LCC.
Section
PCU
Case 1
Cause
Connector and harness connection trouble or
disconnection, LCC control PWB trouble, power unit
trouble
Check
Check the connector and the harness of the power
and
line. Check that the power unit and the LCC control
remedy
PWB is of 24V.
U6-50
Desk incompatibility trouble
Trouble content
Detection of desk connection incompatible with the
MX-2300/2700 **
Section
PCU
Case 1
Cause
Connection of a desk which is incompatible with the
MX-2300/2700 ** is detected.
Check
Connect the MX-DEX1/DEX2.
and
remedy
U6-51
LCC incompatibility trouble
Trouble content
Detection of LCC connection which is incompatible
with the MX-2300/2700 **.
Section
PCU
Case 1
Cause
Connection of the LCC, which is incompatible with the
MX-2300/2700 ** is detected.
Check
Connect the MX-LCX1.
and
remedy
MX-2300/2700 N/G SELF DIAG AND TROUBLE CODE 8 – 27
UC-02 CPT-ASIC abnormality
Trouble content
CPT-ASIC access error (When the ASIC does not
operate normally.)
Section
Scanner
Case 1
Cause
CPT-ASIC abnormality, SCU PWB abnormality
Check
Turn OFF/ON the power several times. If the trouble
and
still occurs, replace the SCU PWB or the CPT-ASIC.
remedy
UC-20 Document control module trouble
Trouble content
Communication error between SCU and DOCC
Communication line test error when turning on the
power or after canceling an exclusion simulation.
Section
Scanner
Case 1
Cause
Connector or harness connection error or
disconnection
Check
Check the connector and harness in the
and
communication line.
remedy
Case 2
Cause
Control PWB (SCU) trouble, DOCC PWB trouble.
Check
Replace the SCU PWB or the DOCC PWB.
and
remedy
Case 3
Cause
Malfunction due to electrical noises.
Check
Turn OFF/ON the power to electrical cancel the
and
trouble.
remedy