44-13
Purpose
: Adjustment
Function (Purpose) : Color image density sensor adjustment
(Adjustment by the jig)
Section
: Process
Item
: Operation
Operation/Procedure
1)
When [EXECUTE] button is pressed, it is highlighted, and the
color sensor adjustment is started by using the patch seal.
* After completion of the color sensor adjustment, [EXECUTE]
button returns to the normal display, and the set content is
displayed. At that time, the necessary data are saved to
EEPROM and RAM.
* When [EXECUTE] button is pressed during the sensor
adjustment, the sensor adjustment is interrupted and [EXE-
CUTE] button returns to the normal display.
* In case of an adjustment error, "ERROR" is displayed in the
value display section at the right of the error item. No data
are saved to EEPROM, and the operation is terminated.
[EXECUTE] button returns to the original state.
<Operation contents>
1)
The target value of CL is set and the LED emitting level is
adjusted, and the operation is terminated.
<Display item and content description>
Item
Display item
Description
A
PCS_CL
Calibration plate
CARB OUT
sensor value
B
PCS_CL
Color dark voltage
DARK
C
PCS_CL LED
Color sensor light
ADJ
emitting quantity
adjustment value
SIMULATION NO.44 13
TEST
PATCH SEAL ADJUSTMENT
:
108
PCS
CL CARB OUT
0
:
PCS CL DARK
21
:
PCS CL LED ADJ
44-14
Purpose
: Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose) : Used to check the output level of the fusing
temperature sensor, the machine tempera-
ture sensor, and the humidity sensor.
Section
: Process
Item
: Operation
Operation/Procedure
1)
The machine enters this simulation, the current data are dis-
played.
* If there is a page over [↑], an active display is shown and the
page moves up. If there is no page upward, the display
grays out and the operation is invalid.
If there is a page under [↓], an active display is shown and
the page moves down. If there is no page downward, the
display grays out and the operation becomes invalid.
* Data are revised every 5sec.
* For the temperature and humidity only, data outside the range
are displayed as "-".
Set
Default
Writing
range
value
1 to 255
108
YES
0 to 255
0
NO
1 to 255
21
YES
0
CLOSE
EXECUTE
1/1
MX-2300/2700 N/G SIMULATION 7 – 56
<Display item and description>
Display item
Description
TH_UM
Fusing upper
thermister main A/D
value (Temperature
°C/AD value)
TH_UM_AD1
Fusing upper
thermistor main
compensation
sensor temperature
(°C)
AD value (AD value)
TH_UM_AD2
Fusing upper
thermistor main
sensor AD value
(AD value)
TH_LM
Fusing lower
thermister main A/D
value (Temperature
°C/AD value)
TH_US
Fusing upper
thermister sub A/D
value (Temperature
°C/AD value)
TEMPRATURE
Temperature
thermister
(Temperature/AD
value)
HUMIDITY
Humidity sensor
(Humidity/AD value)
TH1_LSU
Thermister 1 A/D
value (Temperature
°C/AD value)
* The above display range is converted into hexadecimal number
to display the AD value.
* When the door open, the power of the sensor would be down, so
that the sensor display is treated as outside the range.
* "°C" is displayed as "deg" on the panel because of the display
fonts.
SIMULATION NO.44-14
TEST
SENSOR DATA DISPLAY MONITOR
:
TH_UM
:
TH_UM_AD1
:
TH_UM_AD2
:
TH_LM
:
TH_US
44-16
Purpose
: Adjustment/Setup/Operation data output/
Check (Display/Print)
Function (Purpose) : Used to check data related to the toner
density correction result. (This simulation
allows to check that the correction is nor-
mally performed or not.)
Section
: Process (Developing)
Item
: Operation
Operation/Procedure
1)
When the machine enters Simulation 44-16, the screen on the
right is displayed.
Specify the color with [K][C][M][Y] buttons. (In this example, [K]
is selected.) The data of the selected color are displayed.
* Only one color button can be selected. When a color button
is selected, it is highlighted. (Black ([K]) is selected in the ini-
tial state.)
Default
Display range
value
Temperature:
Sensor
0 to 255 °C (±1°C)
value
AD value: 0 to 1023
Temperature:
Sensor
0.0 to 255.0 °C
value
(±0.2°C)
AD value: 0 to 1023
AD value: 0 to 1023
Sensor
value
Temperature:
Sensor
0 to 255 °C (±1°C)
value
AD value: 0 to 1023
Temperature:
Sensor
0 to 255 °C (±1°C)
value
AD value: 0 to 1023
Temperature: –40.0 to
Sensor
60.0°C (±0.1°C)
value
AD value: 0 to 1023
Humidity:
Sensor
5.0 to 90.0% (±0.1%)
value
AD value: 0 to 1023
Humidity:
Sensor
5.0 to 60.0 °C
value
(±0.1°C)
AD value: 0 to 255
CLOSE
255deg / XXX
255.0deg / XXX
XXX