43-24
Purpose
: Setting
Function (Purpose) : Used to enter the correction values for SIM
43-1 and SIM 43-4 temperature correc-
tions.
Section
: Fusing
Item
: Operation
Operation/Procedure
1)
Select the set item with [↑] and [↓] buttons.
The highlighted section of the set value is switched and dis-
played on the set setting area.
* If there is any item over [↑], an active display is made and
item is shifted.
If there is no item over [↑], the display grays out and the
operation is invalid.
If there is any item under [↓], an active display is made and
item is shifted.
If there is no item over [↓], the display grays out and the
operation is invalid.
<Set range and default value of each setup>
Item
Display items
A
NN_120_ WUP_HL_UM & HL_US
B
NN_120_WUP_HL_LM
C
LL_120_WUP_HL_UM & HL_US
D
LL_120_WUP_HL_LM
E
HH_120_WUP_HL_UM & HL_US
F
HH_120_WUP_HL_LM
G
ON_120_WUP_HL_UM
H
ON 120 WUP HL_US
I
NN_120_ FUS_DUP_HL_UM & HL_US
J
NN_120_ FUS_DUP_HL_LM
K
LL_120_ FUS_DUP_HL_UM & HL_US
L
LL_120_ FUS_DUP_HL_LM
M
HH_120_ FUS_DUP_HL_UM & HL_US
N
HH_120_ FUS_DUP_HL_LM
O
NN_120_ FUS_DUP_CNT
P
LL_120_ FUS_DUP_CNT
Q
HH_120_ FUS_DUP_CNT
R
COOL_DOWN_HEAVY
S
COOL_DOWN_OHP
T
COOL_DOWN_DEVELOP
U
WUP DUP TIME
* On adjustment values
Each temperature correction value → Temperature 1°C change
by 1 count
Each paper exit count → 1 sheet by 1 count
Each cool-down time → 1s change by 1 count
<Code descriptions of the above list>
TH_UM
Fusing upper thermister MAIN center
TH_LM
Fusing lower thermister MAIN
TH_US
Fusing upper thermister SUB edge
HL_UM
Heater lamp upper MAIN
HL_LM
Heater lamp lower MAIN
HL_US
Heater lamp upper SUB
WARMUP end temperature
correction value
Temperature correction value
immediately after completion of
warm-up and during continuation
of temperature correction
Fusing temperature correction
value
Fusing duplex paper exit count
Cool-down time
Temperature correction
continuation time immediately
after completion of warm-up
MX-2300/2700 N/G SIMULATION 7 – 50
2)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
3)
When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
pressed, the entered value is set.
* Input value: The intercept for the correction value is 50. This is
because the set value is kept as a positive number in case of a
negative setting due to negative correction.
• Set value: Value to be set (–49 to +49)
Input value: Actual input value (1 to 99)
Set value
–49
–25
Input value
1
25
Item descriptions
120°C or below when turning
Common to items
on the power under NN
HL_UM, HL_US
environment
Item HL_LM
120°C or below when turning
Common to items
on the power under LL
HL_UM, HL_US
environment
Item HL_LM
120°C or below when turning
Common to items
on the power under HH
HL_UM, HL_US
environment
Item HL_LM
120°C or below when turning
Item HL_UM
on the power
Item HL_US
120°C or below when turning
Common to items
on the power under NN
HL_UM, HL_US
environment
Item HL_LM
120°C or below when turning
Common to items
on the power under LL
HL_UM, HL_US
environment
Item HL_LM
120°C or below when turning
Common to items
on the power under HH
HL_UM, HL_US
environment
Item HL_LM
Under NN environment
Under LL environment
Under HH environment
Heavy paper
OHP
Envelope
-
SIMULATION NO.43-24
TEST
FUSER TEMP RESET
A : 50
NN_120_WUP_HL_UM&HL_US
A:
50
B : 50
NN_120_WUP_HL_LM
C : 50
LL_120_WUP_HL_UM HL_US
1
99
D : 50
LL_120_WUP_HL_LM
–5
0
+5
+25
+49
45
50
55
75
99
Set
Default
range
value
1 to 99
50
1 to 99
50
1 to 99
50
1 to 99
50
1 to 99
50
1 to 99
50
1 to 99
40
1 to 99
55
1 to 99
55
1 to 99
50
1 to 99
60
1 to 99
50
1 to 99
50
1 to 99
50
1 to 60
5
1 to 60
10
1 to 60
5
1 to 60
15
1 to 60
30
1 to 60
40
0 to 255
90
0
CLOSE
OK