Sharp MX-2300 G Service Manual page 181

Digital full color multifunctional system
Hide thumbs Also See for MX-2300 G:
Table of Contents

Advertisement

(Initial screen)
SIMULATION NO.46-28
TEST
AUTO EXPOSURE/ORG AUTO RECOG/MESH LINE RECOG OF CONFIRM
PRESS [EXECUTE] TO SCAN START
(Completion of scan = ACS judgment result screen)
SIMULATION NO.46-28
TEST
AUTO EXPOSURE/ORG AUTO RECOG/MESH LINE RECOG OF CONFIRM
NOW READING THE ORIGINAL.
PLEASE WAIT...
* Press [↓] to display the image process statistic amount, and
press [NEXT] to display the judgment result of "COLOR
AE","ORG RECOG", and"SCR RECOG".
46-33
Purpose
: Setting
Function (Purpose) : Used to execute the color auto mode
adjustment.
Section
: Image process (ICU)
Item
: Image quality
Operation/Procedure
NOTE: Unless a special change is required, keep the default val-
ues except for the following items. For the following items,
change the set values according to the necessity.
COLOR AE(SW MODE 1 - 7 / TH MAX MONO / TH MAX
COLOR / SW NEWS / TH MODE SCR)
ACS(SIM LEVEL)
1)
Select a category to be set with [NEXT] and [BAC] buttons. (In
this example, "ACS4 digits or less" is set.)
2)
Select the set item with [↑] and [↓] buttons.
The highlighted set value is switched and the value is dis-
played in the setting area.
* If there is any item over [↑], an active display is made and
item is shifted.
If there is no item over [↑], the display grays out and the
operation is invalid.
If there is any item under [↓], an active display is made and
item is shifted.
If there is no item over [↓], the display grays out and the
operation is invalid.
3)
Enter the set value with 10-key.
* Press [C] key to clear the entered values.
4)
When [OK], [↑], [↓] button, [COLOR], or [BLACK] key is
pressed, the currently entered data are saved to EEPROM and
RAM.
5)
Select a desired button.
The selected button is highlighted and the value is displayed.
(In the default state, [TH_ACS5 ENLARGE] is highlighted.)
6)
Enter a new value (000000002 in this example) with 10-key.
* The number of digits is max. 9. The 10th digit cannot be
entered. Entry is made after clearing.
* 10-key: [0] to [9]
* Press [C] key to clear the entered values.
7)
When [SET] button is pressed, setting is revised.
0
CLOSE
EXECUTE
0
CLOSE
MX-2300/2700 N/G SIMULATION 7 – 75
* The display in the frame of [NEW] is deleted, and the value
entered in the procedure 6 is displayed in the column of
[PRESENT].
* If a new value if less than 9 digits, revision is not made.
* Switch the category sequentially with [NEXT] and [BACK]
buttons.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-2700 g

Table of Contents