Copy Lead Edge Image Reference Position Adjustment, Image Off-Center, Sub Scanning Direction Image Magnification Ratio Automatic Adjustment; Spf Mode Image Off-Center, Image Lead Edge Position, Sub Scanning Direction Image Magnification Ratio Automatic Adjustment - Sharp MX-2300 G Service Manual

Digital full color multifunctional system
Hide thumbs Also See for MX-2300 G:
Table of Contents

Advertisement

5)
Press [EXCUTE] key.
The adjustment pattern is printed out.
6)
Set the adjustment pattern on the document table. (Any direc-
tion)
Note: Fit the adjustment pattern correctly with the document
guide.
7)
Press [EXCUTE] key.
The following items are automatically adjusted.
* Print image lead edge image position adjustment
* Print image off-center adjustment
8)
Press [OK] key.
The adjustment result becomes valid.
Perform procedures 4) to 7) for each paper feed tray.
27-C Copy lead edge image reference position
adjustment, image off-center, sub scanning
direction image magnification ratio auto-
matic adjustment
1)
Enter the SIM50-28 mode.
SIMULATION NO.50-28
TEST
AUTO IMAGE POSITION ADJUSTMENT : SERVICE
OC ADJ
SPF ADJ
RESULT
2)
Select [OC ADJ] with the key button.
3)
Select the paper feed tray with paper in it with the key button.
(Any paper size will do.)
SIMULATION NO.50-28
TEST
AUTO IMAGE POSITION ADJUSTMENT SERVICE
CS1
MFT
4)
Press [EXCUTE] key.
The adjustment pattern is printed out.
0
CLOSE
BK-MAG ADJ
SETUP/PRINT ADJ
DATA
1/1
0
CLOSE
CS2
EXECUTE
1/1
MX-2300/2700 N/G ADJUSTMENTS 6 – 62
5)
Set the adjustment pattern on the document table. (Any direc-
tion)
Note: Fit the adjustment pattern correctly with the document
guide.
6)
Press [EXCUTE] key.
SIMULATION NO.50-28
TEST
AUTO
IMAGE POSITION
ADJUSTMENT SERVICE
PLEASE SET THE SIT CHART PAPER ON
THEN
PRESS [EXECUTE]
TO START
REPRINT
The following items are automatically adjusted.
Copy lead edge image reference position adjustment,
image off-center, sub scanning direction image magnifica-
tion ratio automatic adjustment
7)
Press [OK] key.
The adjustment result becomes valid.
SIMULATION NO.50-28
TEST
AUTO IMAGE POSITION ADJUSTMENT SERVICE
OC
LEAD
OFFSET
REPRINT
RESCAN
27-D SPF mode image off-center, image lead
edge position, sub scanning direction
image magnification ratio automatic adjust-
ment
Refer to the RSPF (MX-RPX1) SM.
0
CLOSE
THE OC
EXECUTE
0
CLOSE
SUB
RETRY
DATA
OK

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-2700 g

Table of Contents