Sharp MX-2300 G Service Manual page 398

Digital full color multifunctional system
Hide thumbs Also See for MX-2300 G:
Table of Contents

Advertisement

3)
Disconnect the connector, and remove the upper thermistor.
c. Non-contact thermistor
1)
Remove the fusing upper cover.
2)
Remove the screws, and remove the cover. Remove the con-
nector and the screws, then remove the non-contact ther-
mistor.
d. Lower thermostat
1)
Remove the fusing unit.
2)
Remove the fusing lower cover.
3)
Disconnect the connector, and remove the lower thermostat.
e. Lower thermistor
1)
2)
3)
f. Upper heater lamp main
g. Upper heater lamp sub
1)
2)
3)
4)
MX-2300/2700 N/G FUSING SECTION N – 4
Remove the fusing unit.
Remove the fusing lower cover.
Disconnect the connector, and remove the lower thermistor.
Remove the fusing unit.
Release the pressure release lever, and remove the fusing
upper cover F.
Tilt the lock lever, and remove the fusing upper cover R.
1
Disconnect the connector.
1
2
2