F1-36
Finisher punch registration sensor
trouble (MX-FNX2)
Trouble content
Sensor input value abnormality
Section
PCU
Case 1
Cause
Sensor breakage, harness disconnection, saddle
finisher control PWB trouble (MX-FNX2), punch
control PWB trouble (MX-FNX2)
Check
Use SIM3-2 to check the operation of the punch
and
timing sensor (FPTD).
remedy
Replace the finisher punch unit (Replace the punch
control PWB.).
F1-37
Finisher backup RAM trouble
Trouble content
Backup RAM data garbled
Section
PCU
Case 1
Cause
Finisher control PWB trouble, malfunction due to
electrical noises
Check
Replace the finisher control PWB.
and
remedy
F1-38
Finisher punch backup RAM trouble
(MX-FNX2)
Trouble content
Punch unit backup RAM data garbled
Section
PCU
Case 1
Cause
Punch control PWB trouble, malfunction due to
electrical noises
Check
Replace the punch control PWB.
and
remedy
F1-39
Finisher punch dust sensor trouble
(MX-FNX2)
Trouble content
Punch dust sensor detection trouble
Section
PCU
Case 1
Cause
Sensor breakage, harness disconnection, finisher
control PWB trouble (MX-FNX2), punch control PWB
trouble (MX-FNX2)
Check
Use SIM3-2 to check the operation of the sensor
and
punch dust sensor (FPDD).
remedy
Replace the finisher control PWB or the punch control
PWB.
F1-40
Saddle finisher punch power
interruption trouble (MX-FNX2)
Trouble content
When the punch unit power interruption is detected.
Section
PCU
Case 1
Cause
Harness disconnection, punch control PWB trouble
Check
Use SIM3-3 to check the operation punch motor
and
(FPNW).
remedy
Replace the finisher punch unit (Replace the punch
control PWB.).
F1-50
Finisher incompatibility trouble
Trouble content
Detection of finisher incompatible with MX-2700**/
2300**
Section
PCU
Case 1
Cause
Connection of the AR-F13, etc. which is incompatible
with MX-2700**/2300** is detected.
Check
Connect the MX-FNX1/MX-FNX2.
and
remedy
MX-2300/2700 N/G SELF DIAG AND TROUBLE CODE 8 – 15
F2-39
Process thermistor trouble
Trouble content
Process thermistor open
Section
PCU
Case 1
Cause
Process thermistor harness connection trouble
Check
Check the connection of the harness, connector of the
and
process thermistor.
remedy
Case 2
Cause
Process thermistor trouble
Check
Check the connection of the process thermistor.
and
remedy
Case 3
Cause
PCU PWB trouble
Check
Check the PCU PWB.
and
remedy
F2-40
Toner empty sensor abnormality
(BLACK)
Trouble content
Toner empty sensor output abnormality. Sample level
25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check
Check the connection of the connector harness to the
and
PCU PWB. Check the connection of the toner empty
remedy
sensor.
Case 2
Cause
Connector harness trouble
Check
Check the harness disconnection.
and
remedy
Case 3
Cause
Cartridge trouble
Check
Check the cartridge connection.
and
remedy
F2-41
Toner empty sensor abnormality
(CYAN)
Trouble content
Toner empty sensor output abnormality. Sample level
25 or less or 231 or above.
Section
PCU
Case 1
Cause
The connector is not installed.
Check
Check the connection of the connector harness to the
and
PCU PWB. Check the connection of the toner empty
remedy
sensor.
Case 2
Cause
Connector harness trouble
Check
Check the harness disconnection.
and
remedy
Case 3
Cause
Cartridge trouble
Check
Check the cartridge connection.
and
remedy