• When the set value is changed by 1, the position is shifted by
0.1mm.
• Since the distance of RRCA-S and RSPF scan position is
changed, RRCA and RRCA-S are not changed by this adjust-
ment value.
SIMULATION NO.53-08
TEST
SPF SCANNING POSITION ADJUSTMENT
A
50
ADJUST VALUE
A:
50
[ 1 ~ 99 ]
55
55-1
Purpose
: Setting
Function (Purpose) : Used to set the engine soft SW.
Section
: PCU
Item
: Operation (Specifications)
Operation/Procedure
1)
When the machine enters Simulation 55-01, the screen on the
right is displayed.
* On the initial screen, [SW-NO.] button is highlighted.
2)
With [SW NO.] button highlighted, enter the SW number with
10-key.
* Press [C] key to clear the entered values.
3)
Press [DATA] button.
[DATA] button is highlighted and the current set value is dis-
played.
4)
With [DATA] button highlighted, enter the bit data with 10-key.
When 10-key corresponding to the bit is pressed, the bit data
display is switched as shown below.
[1] → [0]
[0] → [1]
* Entry of 1 to 8 only is effective.
5)
When [EXECUTE] button is pressed, the currently entered
data are set.
After completion of setting, [EXECUTE] button returns to the
normal display.
SIMULATION NO.55-01
TEST
ENGINE SOFT SW. SETTING
SW NO.
AAA
(SW No.1-16)
:
DATA
1 2 3 4 5 6 7 8
:
1 2 3 4 5 6 7 8
55-2
Purpose
: Setting
Function (Purpose) : Used to set the scanner soft SW
Section
: Scanner
Item
: Operation (Specifications)
Operation/Procedure
1)
When the machine enters Simulation 55-02, the screen on the
right is displayed.
* On the initial screen, [SW-NO.] button is highlighted.
2)
3)
0
4)
CLOSE
5)
OK
55-3
Purpose
Function (Purpose) : Used to set the controller soft SW.
Section
Item
Operation/Procedure
1)
2)
3)
4)
0
CLOSE
5)
EXECUTE
MX-2300/2700 N/G SIMULATION 7 – 109
With [SW NO.] button highlighted, enter the SW number with
10-key.
* Press [C] key to clear the entered values.
Press [DATA] button.
[DATA] button is highlighted and the current set value is dis-
played.
With [DATA] button highlighted, enter the bit data with 10-key.
When 10-key corresponding to the bit is pressed, the bit data
display is switched as shown below.
[1] → [0]
[0] → [1]
* Entry of 1 to 8 only is effective.
When [EXECUTE] button is pressed, the currently entered
data are set.
After completion of setting, [EXECUTE] button returns to the
normal display.
SIMULATION NO.55-02
TEST
SCANNER SOFT SW. SETTING.
SW NO.
AAA
(SW No.1-16)
DATA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
: Setting
: MFP
: Operation (Specifications)
When the machine enters Simulation 55-03, the screen on the
right is displayed.
* On the initial screen, [SW-NO.] button is highlighted.
With [SW NO.] button highlighted, enter the SW number with
10-key.
* Press [C] key to clear the entered values.
Press [DATA] button.
[DATA] button is highlighted and the current set value is dis-
played.
With [DATA] button highlighted, enter the bit data with 10-key.
When 10-key corresponding to the bit is pressed, the bit data
display is switched as shown below.
[1] → [0]
[0] → [1]
* Entry of 1 to 8 only is effective.
When [EXECUTE] button is pressed, the currently entered
data are set.
After completion of setting, [EXECUTE] button returns to the
normal display.
SIMULATION NO.55-03
TEST
MFP SOFT SW. SETTING.
SW NO.
AAA
(SW No.1-16)
DATA
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
0
CLOSE
EXECUTE
0
CLOSE
EXECUTE