6-2
Purpose
: Operation test/check
Function (Purpose) : Used to check the operations of each fan
motor and its control circuit.
Section
: Other
Item
: Operation
Operation/Procedure
1)
Select the item to be checked with the buttons on the touch
panel.
2)
Press [EXECUTE] button.
The selected load operation is performed.
When [EXECUTE] button is pressed, the operation is termi-
nated.
POFM
Paper exit cooling fan motor (* POFM_U, POFM_F, and
POFM_R are driven at the same time.)
OZFM
Ozone fan motor
PSFM
Power cooling fan motor
SIMULATION NO.06 02
TEST
FAN LOAD SETUP
POFM
PSFM
6-3
Purpose
: Operation test/check
Function (Purpose) : Used to check the operations of the primary
transfer unit and the related circuit.
Section
: Process (Transfer)
Item
: Operation
Operation/Procedure
1)
Press [EXECUTE] button.
2)
The load operation is started. (Separation operation: BLACK
→ COLOR → FREE Stops at each position for 5 sec.) During
the operation, the current position is displayed.
BLACK
Black mode position
COLOR
COLOR mode position
FREE
Drum separation position
SIMULATION NO.06 03
TEST
TRANSFER LOAD CHECK
:
POSITION
0
CLOSE
OZFM
EXECUTE
1/1
Black mode position
→ COLOR mode position
→ Drum separation position
→ Shift to the black mode
position is repeated.
0
CLOSE
EXECUTE
1/1
MX-2300/2700 N/G SIMULATION 7 – 15
7
7-1
Purpose
: Setting
Function (Purpose) : Used to set the operating conditions of
aging.
Section
: Other
Item
: Operation
Operation/Procedure
1)
Select the target to be set with buttons on the touch panel.
2)
Press [EXECUTE] button.
The machine is rebooted in the aging mode.
The contents set with this simulation are retained until the
power is turned OFF.
AGING
Aging operation setup
INTERVAL
Intermittent setup
MISFEED DISABLE
JAM detection enable/disable setup
FUSING DISABLE
Fusing operation enable/disable setup
WARMUP DISABLE
Warm-up disable setup
DV CHECK DISABLE
DV unit detection enable/disable setup
SHADING DISABLE
Shading disable setup
CCD GAIN FREE
CCD gain adjustment free setup
SIMULATION NO.07 01
TEST
AGING TEST SETTING
AGING
MISFEED DISABLE
WARMUP DISABLE
SHADING DISABLE
7-6
Purpose
: Setting
Function (Purpose) : Used to set the intermittent aging cycle.
Section
: Other
Item
: Operation
Operation/Procedure
1)
Enter the intermittent aging cycle (unit: sec) with 10-key.
2)
Press [OK] button.
The time entered in procedure 1) is set.
Item
Item
A
CYCLE TIME(SEC)
SIMULATION NO.07-06
TEST
INTERVAL AGING CYCLE TIME SETUP
A
3
CYCLE TIME(SEC)
A:
3
1
900
0
CLOSE
INTERVAL
FUSING DISABLE
DV CHECK DISABLE
CCD GAIN FREE
EXECUTE
1/1
Set range
Default value
1 to 900
3
0
CLOSE
OK