If you want all parameters of the DCA group to be subject to Recall Safe, turn on the ALL button.
Unlike when a channel is selected, Recall Safe will be enabled for that DCA group the moment
you turn on either the LEVEL/ON button or the ALL button.
5.
To enable Recall Safe for the selected channel, turn on the SAFE button in the SAFE
PARAMETER SELECT field. (If you have selected a DCA group, turn on either the
LEVEL/ON button or the ALL button.)
Channels or DCA groups for which Recall Safe is enabled will be highlighted in the CH RECALL
SAFE field.
6.
To enable Recall Safe for global parameters, turn on the buttons in the GLOBAL
RECALL SAFE field.
These buttons correspond to the following parameters.
INPUT PATCH
All input patches
INPUT NAME
All input channel names
OUTPUT PATCH
All output patches
OUTPUT NAME
All output channel names
HA
All I/O racks, and HA-related parameters for external head amps
CH LINK
All channel link group settings
GEQ RACK
Apply Recall Safe to GEQ racks 1–16, Effect racks 1–8, Premium Racks
EFFECT RACK
1–8 individually.
PREMIUM RACK
PANEL SNAPSHOT
Fader bank selections, Master fader assignments
NOTE
If a dual-type GEQ rack or Premium Rack has been selected, you can apply Recall Safe to rack
A and B individually. For other racks, the Recall Safe setting for racks A and B will be linked.
7.
When you have finished making settings, press the CLOSE button to close the
popup window. Then perform a Recall operation.
Only the selected DCA group channels and parameters will be excluded from Recall operations.
Channel Link (see
page
69) and bus settings are not subject to Recall Safe. They will always be
reproduced in the recalled scene.
This means that if Recall Safe is enabled for one of several channels included in a link group or
one of two channels set to stereo, the parameter settings of that channel may differ from those of
the other channel(s). In such cases, the applicable parameter will be automatically re-linked the
next time it is operated.
You can globally apply Recall Safe to channel links by using the global parameter.
NOTE
• You can use the Recall Safe function along with the Focus function (see
parameters that are excluded from Recall operations by either Focus or Recall Safe will not be
recalled.
• If you perform a Recall operation while holding down a [SEL] key, the Recall Safe settings for the
corresponding channel will temporarily be enabled for that Recall operation.

Using the Fade function

"Fade" is a function that smoothly changes the faders of specified channels and DCA groups to their
new values over a specified duration when you recall a scene. The settings of the Fade function are made
independently for each scene.
1.
Press the SCENE field in the Function Access Area.
The SCENE LIST window will appear, in which you can perform various operations for scene
memory.
2.
Press the FADE TIME tab at the bottom of the SCENE LIST window.
You can use tabs to switch the right half of the SCENE LIST window among three different fields.
In this case, press the tab to make the FADE TIME field appear.
1
page
86). Channels or
SET popup button
Press this button to open the FADE TIME popup window, in which you can select a channel for
which you want to use the Fade function, and specify the fade time (the duration of time over
which the fader will reach its new value).