■ MONITOR DELAY field
This field enables you to specify the monitor delay setting by which the monitor out signal is delayed.
B
AUTO BYPASS button
Turn this on to automatically bypass monitor delay when the cue is on.
C
MONITOR DELAY knob
Indicates the currently-specified delay time. The millisecond value is indicated above the knob,
and the delay time value in currently-selected units and the currently-selected scale type are
indicated below the knob. However, if you have selected ms as the scale, the delay time value will
not appear above the knob.
Press this knob and you will be able to use the multifunction knob to adjust the value.
■ Meter field
This field indicates the monitor output level.
D
Meters
Indicates the output level of the monitor L/R/C channels.
E
MONITOR OUT PATCH button
Press this button to open the PORT SELECT popup window, in which you can select an output
port to patch to the monitor out L/R/C channels.
4.
Use the buttons of the SOURCE SELECT field to select a monitor source.
In the SOURCE SELECT field you can select only one monitor source. However, if you have
selected DEFINE, you can use the ASSIGN field to specify multiple monitor sources.
The following table shows the monitor sources that you can select in the ASSIGN field.
MIX 1–24
Output signals of MIX channels 1–24
MTRX 1–8
MATRIX buses 1–8 output signals
STEREO
STEREO L/R channel output signals
MONO (C)
MONO channel output signal
OMNI 1–2 – OMNI 7–8
OMNI IN jacks 1–8 input signals (per two channels)
PB OUT
Recorder's PLAYBACK OUT signals
NOTE
You can select a maximum of eight monitor sources in the ASSIGN field. If you select eight
monitor sources, no further selections will be possible. Please turn off the buttons for unneeded
sources.
5.
To specify a port as the output destination for monitor signals L, C, and R, press
one of the output select buttons (L/R/C) in the meter field to open the PORT
SELECT popup window. In this window, choose from the following monitor signal
output destinations (multiple selections are allowed).
DANTE 1–64
Output channels 1–64 to audio network
OMNI1–8
OMNI OUT jacks 1–8
DIGI OUT L/R
DIGITAL OUT jack on the CL unit
SLOT1–1 – SLOT3–16
Output channels 1–16 of an I/O card installed in slots 1–3
When you have selected an output port, press the CLOSE button to close the popup window.
In the same way, specify the output ports for MONITOR OUT L, R, and C.
NOTE
• If desired, you can specify output ports only for MONITOR OUT L and R to monitor through two
speakers.
• If you have not specified an output port for MONITOR OUT C, selecting the MONO (C) button or
LCR button as the monitor source will automatically cause the MONO channel signal to be
distributed to MONITOR OUT L/R.
6.
To enable monitoring, press the OUTPUT button to turn it on.
The monitor source you selected in step 4 will be sent to the output destination you specified in
step 5.
NOTE
The PHONES Out jack will always output the monitor signal, regardless of whether the OUTPUT
button is on or off.
7.
To control the monitor fader, press the Bank Select [STEREO] key in the Centralogic
section, and then operate the monitor fader.