Yamaha CL5 Reference Manual page 254

Dgital mixing console yamaha cl5; cl3; cl1
Hide thumbs Also See for CL5:
Table of Contents

Advertisement

4.8
FUNCTION CALL – CHANNEL –
4.8.1 Pair ON/OFF Trigger Format (PARAMETER CHANGE)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[PARAMETER CHANGE ECHO] is on.
STATUS
11110000 F0
System exclusive message
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 1n
GROUP ID
00111110 3E
Digital mixer
CL Series
MODEL ID
00010010 19
OTHER DATA
DATA CATEGORY 00000000 00
FUNCTION NAME 01000011 "C"
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
DATA
0sssssss sh
Source Channel Number H *1)
Source Channel Number L *1)
0sssssss sl
Destination Channel Number H *1)
0ddddddd dh
0ddddddd dl
Destination Channel Number L *1)
End of exclusive
EOX
11110111 F7
4.8.2 Module Name
Module Name
Pair On (with Copy)
"PAIRONCP"
Pair On (with Reset Both)
"PAIRONRS"
Pair Off
"PAIROFF_"
*1)
0 :CH1
- 71:CH72
256 :MIX 1
- 279:MIX 24
512 :MATRIX 1 - 519: MATRIX 8
4.9 LEVEL METER DATA
4.9.1 Format (PARAMETER CHANGE)
When transmission is enabled by receiving Request for Level Meter, the corresponding
metering data will be sent in every 50 millisecond for 10 seconds. If metering
information is expected to be continuously sent, Request is needed to be sent in at least
every 10 seconds.
Receive
The data will be echoed when [PARAMETER CHANGE ECHO] is ON.
Transmission
When transmission is enabled by receiving Request, the corresponding metering data
will be sent in constant interval for a given period of time (The interval and time will
vary depending on devices). When rebooted or port setting is changed, the
transmission will be disabled.
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
Digital mixer
GROUP ID
00111110 3E
CL Series
MODEL ID
00010010 19
REMOTE LEVEL METER
DATA CATEGORY 00100001 21
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Data1
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
4.9.2 Format (PARAMETER REQUEST)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[PARAMETER CHANGE ECHO] is on. the corresponding metering data will be sent
via [Rx CH] in constant interval for a given period of time (The interval and time will
vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be
immediately stopped [disabled].
Transmission
When [PARAMETER CHANGE ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
SUB STATUS
0011nnnn 3n
n=0-15 (Device number=MIDI Channel)
Digital mixer
GROUP ID
00111110 3E
CL Series
MODEL ID
00010010 19
REMOTE LEVEL METER
DATA CATEGORY 00100001 21
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
0ccccccc cl
Count L
End of exclusive
EOX
11110111 F7
254
Appendices
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl3Cl1

Table of Contents