INPUT/OUTPUT tabs
Use these tabs to switch between the INPUT METER screen and OUTPUT METER screen.
Input level and meter display
This area displays the meter and fader for each input channel.
1
2
3
4
5
1
Channel number
Indicates the channel number.
2
Σ clipping indicator
Lights to indicate that a signal is clipping at some point in the channel.
3
OVER indicator
Lights if the signal is clipping at the input section of the input channel.
4
Meter
Indicates the input level of the input channel.
5
Fader
The input level is indicated by the fader position and a numeric value (in dB) that appears
immediately below the fader.
NOTE
Press any part of the meter area to assign the corresponding fader bank to the Centralogic
section.
Centralogic fader display
This area displays the level of the faders currently set in the Centralogic section.
METERING POINT field
Select one of the following as the metering point at which the level will be detected.
■ For INPUT METER
• PRE HPF.................... Immediately before the HPF
• PRE FADER .............. Immediately before the fader
• POST ON................... Immediately after the [ON] key
■ For OUTPUT METER
• PRE EQ ...................... Immediately before the EQ
• PRE FADER .............. Immediately before the fader
• POST ON................... Immediately after the [ON] key
NOTE
On the CL3 or CL1 console, the metering point for output channels will also affect the optional
meter bridge (MBCL).
PEAK HOLD button
Turn on this button to hold the peak level indication on each meter. Turn off this
button to clear the peak hold indication.
2.
If necessary, press a meter point select button to switch the
metering point.
The metering point for the level meters can be set independently for input channels and output
channels.
3.
If you want the peak levels of the level meter to be held, press the PEAK HOLD
button to turn it on.
PEAK HOLD button on/off operations will affect both input channels and output channels as well
as the MBCL meter bridge. When you turn this button off, the peak level indications that had
been held will be cleared.
NOTE
You can also assign the PEAK HOLD button on/off function to a USER DEFINED key
(see
page
164).