Tig Program Sequence ("Program Steps" Mode); Tig Parameter Overview; Mma Welding - EWM Phoenix 335 Progress Puls FA KGE Operating Instructions Manual

Table of Contents

Advertisement

Design and function

MMA welding

5.8.7

TIG program sequence ("Program steps" mode)

5.8.7.1

TIG parameter overview

Basic parameters
Item
Meaning/explanation
1
Gas pre-flow time
2
P
START
Ignition current
3
Duration (start program)
4
Slope duration from P
5
P
(main program)
A
Welding current, absolute
6
Duration (P
7
P
(reduced main program)
B
Welding current
8
Duration (reduced main program)
9
Slope duration from P
10
P
(end program)
END
Welding current
11
Duration (end program)
12
Gas post-flow time
13
Superpulsing
P
, P
, and P
START
B
general welding current setting.
5.9
MMA welding
Risk of being crushed or burnt.
When replacing spent or new stick electrodes
Switch off machine at the main switch
Wear appropriate safety gloves
Use insulated tongs to remove spent stick electrodes or to move welded workpieces and
Always put the electrode holder down on an insulated surface.
86
2
4
sec
3
1
13
sec
Super-
puls
to P
START
A
)
A
to P
A
END
are relative programs whose welding current settings are a percentage based on the
END
8
DYN
sec
sec
5
6
sec
7
Figure 5-49
CAUTION
9
10
sec
sec
sec
11
12
Setting range
0 s to 0.9 s
0% to 200%
0 s to 20 s
0 s to 20 s
5 A to 550 A
0.01 s to 20.0 s
1% to 100%
0.01 s to 20.0 s
0 s to 20 s
1% to 100%
0 s to 20 s
0 s to 20 s
on/off