Advertisement

Design and function
MIG/MAG welding

5.7.14.6 Example, visible seams (latched super pulse)

I
Basic parameters
Welding parameter
GASstr
GASend:
RUECK
PROC.SP.
"P
" start program
START
Welding parameter
DVstart
ustart
tstart
"P
" main program
A
Welding parameter
tS1
DV3
t2
tS3
"P
" reduced main program
B
Welding parameter
tS2
DV3
U3
t3
"P
" end-crater program
END
Welding parameter
tSend
DVend
Uend
tend
60
P
START
P
P
A
P
B
Meaning / explanation
Gas pre-flow time
Gas post-flow time
Wire burn-back length
Travel speed to determine the a-measurement*
Meaning / explanation
Wire speed
Arc length correction
Duration
Meaning / explanation
Slope duration from P
Setting the wire speed
Duration
Slope duration from P
Meaning / explanation
Slope duration from P
Wire speed
Arc length correction
Duration
Meaning / explanation
Slope duration from P
Wire speed
Arc length correction
Duration
P
P
A
A
A
P
P
B
B
Figure 5-32
to P
START
A
to P
B
A
to P
A
B
or P
to P
A
B
END
P
END
t
Setting range
0.0s to 20.0s
0.0s to 20.0s
2 to 500
10cm to 200cm
Setting range
0% to 200%
-9.9V to +9.9V
0.0s to 20s
Setting range
0.0s to 20s
0% to 200%
0.1s to 20s
0.0s to 20s
Setting range
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.1s to 20s
Setting range
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.0s to 20s