Design and function
TIG welding
5.7.7
TIG program sequence ("Program steps" mode)
5.7.7.1
TIG parameter overview
Basic parameters
Item
Meaning/explanation
1
Gas pre-flow time
2
P
START
Ignition current
3
Duration (start program)
4
Slope duration from P
5
P
(main program)
A
Welding current, absolute
6
Duration (P
7
P
(reduced main program)
B
Welding current
8
Duration (reduced main program)
9
Slope duration from P
10
P
(end program)
END
Welding current
11
Duration (end program)
12
Gas post-flow time
13
Superpulsing
P
, P
, and P
START
B
general welding current setting.
84
2
4
sec
5
sec
3
6
1
13
sec
Super-
puls
to P
START
A
)
A
to P
A
END
are relative programs whose welding current settings are a percentage based on the
END
8
DYN
sec
sec
sec
7
11
Figure 5-48
Setting range
0 s to 0.9 s
0% to 200%
0 s to 20 s
0 s to 20 s
5 A to 550 A
0.01 s to 20.0 s
1% to 100%
0.01 s to 20.0 s
0 s to 20 s
1% to 100%
0 s to 20 s
0 s to 20 s
on/off
9
10
sec
sec
12
099-005023-EW501
09.08.2010
Need help?