Mig/Mag Overview Of Parameters - EWM Phoenix 335 Progress Puls FA KGE Operating Instructions Manual

Table of Contents

Advertisement

5.7.14.2 MIG/MAG overview of parameters

Basic Parameters
Item
Meaning / Explanation
1
Gas pre-flow time
2
P
START
Wire speed, relative
Arc length correction
3
Duration
4
Slope duration from P
5
P
A
Wire speed, absolute
6
Dynamics
7
Duration (spot time and superpulse)
8
P
B
Wire speed, relative
Arc length correction, relative
9
Duration
10
Slope duration from P
11
P
END
Wire speed, relative
Arc length correction
12
Duration (superpulse)
13
Gas post-flow time
14
Superpulses
In the factory setting, P
percentages of the wire feed value from the main program P
099-005183-EW501
17.12.2010
2
4
sec
5
sec
3
7
1
14
sec
Super-
puls
to P
START
A
to P
A
END
, P
, and P
START
B
6
9
DYN
sec
10
sec
sec
8
12
Figure 5-28
Setting Range
0.0s to 20.0s
1% to 200%
-9.9V to +9.9V
0.0s to 20.0s
0.0s to 20.0s
0.1 m/min to 40 m/min
-40 to +40
0.01s to 20.0s
1% to 200%
-9.9V to +9.9V
0.01s to 20.0s
0.0s to 20s
1% to 200%
-9.9V to +9.9V
0.0s to 20s
0.0s to 20s
On / Off
NOTE
are "relative programs". They relate to
END
Design and function
MIG/MAG welding
11
sec
sec
13
.
A
57