7.2.2

Resetting all JOBs

Display
7.3

General operating problems

7.3.1

Interface for mechanised welding

No function of the external shut-down devices (emergency stop switch)!
If the emergency stop circuit has been realised using an external shut-down device via
the interface for mechanised welding, the device must be set for this setup. If this is not
observed, the power source will ignore the external shut-down devices and will not shut
down!
Disconnect jumper 1 on PCB T320/1 (Tetrix) or M320/1 (Phoenix / alpha Q)!
099-005183-EW501
17.12.2010
JOB-
LIST
m /m in
Setting/selection
Reset to factory settings
The RESET will be done after pressing the button.
The menu will be ended when no changes are done after 3 sec.
Figure 7-2
WARNING
Rectifying faults
General operating problems
JOB-
LIST
101