Management Agent
Parameter
Power Control
Refresh
Connection Blade Mode
Reset Interface Settings
Stacking State
Inter-Switch Link Setting
3.3.7 User Management
The User Management option is used to change, add and delete users.
The following four user types (roles) with different permission rights are possible:
1. Administrator
2. OEM
3. Operator
4. User
The access rights of the various user roles are as follows:
Administrator
This role allows the user
– to create, update, and delete a user account
– to configure system settings related to the MMB, connection blades, and server blades
– to use commands on the iRMC controller as a result of IPMI permission level assignments of LAN/Serial
for administrators
– to use the functions at the usual user interfaces (Web UI, CLI etc.)
OEM
This role allows the user
– to have the same functions as the Administrator and
– to use OEM commands and functions on the iRMC controller
Operator
This role allows the user
– to use commands on the iRMC controller as a result of IPMI permission level assignments of LAN/Serial
for operators
– to use the functions at the usual user interfaces (Web UI, CLI etc.)
User
This role allows the user
– to use the functions at the usual user interfaces (Web UI, CLI etc.)
26
Description
Starts rebooting the connection blade.
Enables/disables the refresh function.
GbE connection blades can run in two different modes – Switch and IBP. The mode
enabled is displayed here.
Sets the configuration settings to default.
Applies for Connection Blade GbE Switch/IBP 36/8+2 (SB11). These can be intercon-
nected to form a stack. Possible state: Master or Member.
Applies for Connection Blade GbE Switch/IBP 36/8+2 (SB11). Two SB11s which are
operated in a fabric (horizontally adjacent to each other) can be interconnected to
form "one" connection blade. A common management interface then exists for the
connected connection blades.