2-15. FILTERING SYSTEM
(Continued)
305
Pump Removal
(Continued)
4. To replace the pump and motor assembly, insure the
main power has been removed from the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
5. Remove the cover from the junction box and remove the
wire nuts attaching wires leading into the fl exible conduit
going to the motor.
6. Loosen the two screws securing the fl exible conduit to
the 90º conduit connector (8). (Refer to Figure 3-25.)
7. Remove tubing to the pump. (Refer to Figures 3-21
and 3-24.)
8. Remove hardware attaching the motor to the motor base
bracket and remove motor and pump assembly.

Filter Pump Motor

Protector - Manual Reset
The fi lter pump motor is equipped with a manual reset button in
the event the motor's thermal protector actuates. This reset button
is located on the rear of the motor. Wait approximately 5 minutes
before attempting to reset this protector device.
To prevent burns caused by splashing shortening, the
unit's main power switch must be in the OFF position
before resetting the fi lter pump motor's manual reset
protection device.
Model 500/600
2-51