Henny Penny 500 Technical Manual page 14

Cfa pressure fryer electric/gas
Hide thumbs Also See for 500:
Table of Contents

Advertisement

Problem
Peanut oil heating slowly
1-10
Cause
HEATING OF PEANUT OIL SECTION (Continued)
• Low or improper amps
• Low or improper voltage
• Weak or burnt out
elements (elec. model)
• Burnt or charred connectors
• Faulty contactor (electric models)
• Wire(s) loose
• Supply line too small - low
gas volume (gas models)
• Improper ventilation
system (gas models)
Model 500/600
Correction
• See Infomation Mode 16
for present amperage; or
see Information Modes 4, 5, 6,
7, 8, 9, for more information
on this problem; Diagnostic
Mode D 4 gives present day's
heating performance
• See Diagnostic Modes D 3 &
D 4 for present day's voltage
and heating performance; or
see Information Modes 4, 5, 6,
7, 8, 9, and 15 for more infor-
mation on this problem
• See Diagnostic Modes D 4;
see if
"CHECK
COILS, CONTACTORS
AND WIRING"
shows on
display; if so, have fryer
checked by a certifi ed service
technician
• Have wires tightened
• Increase supply line size;
refer to installation
instructions
• Refer to installation
instructions
305