1-5. DIAGNOSTIC MODE
DETAILS (Continued)
1-26
The number of
"WAS NOT READY"
of peanut oil is also reported. Note that this value does not yet
include the not ready warnings generated today.
"D6: BEFORE TODAY,"
"D6: COOKED"
"D6: BEFORE READY"
"D6: 8 TIMES"
"D6: ON THIS OIL"
(Press
)
Finally, the controller identifi es how many times the not ready
warning was generated for the previous batch of peanut oil:
"D6: LAST OIL,"
"D6: COOKED"
"D6: BEFORE READY"
"D6: 24 TIMES"
D 7: "Stopped Too Soon" Report
This section shows how many Cook Cycles were stopped early by
the user, before the cook timer had counted down to 0:00 and the
"*DONE*"
indication was given. This is strictly a user error.
Cycles that are canceled after cooking for less than 30 seconds are
not counted here. For example, if a cycle is accidentally started,
and the Cook Cycle is canceled after just a few seconds, this cycle
will not be counted as a Stopped Too Soon Cycle.
Also, some allowance is given for stopping a cycle a little early.
The user can cancel the cycle up to 10 seconds early without
penalty.
Otherwise, however, any cycle that was stopped with more than 10
seconds remaining
(0:10)
Stopped Too Soon Cycle.
The fi rst item displays what percent of cycles today were stopped
with more than 0:10 remaining. All products are grouped into one
count.
"D7: 8% OF LOADS"
"D7: WERE STOPPED"
"D7: TOO SOON"
"D7: TODAY"
(Press
)