1-6. INFORMATION MODE
DETAILS
1-40
11. OUTP H* P_
This mode displays the status of components and outputs. If the
output signal is detected, an identifying letter is displayed (see
below), followed by an "*". If the output is off,
H = Heat output
P = Pressure output
If heat is on,
"H*"
shows in display. If heat is off,
display. If controls senses a problem with the heat output,
shows in display, with the
If pressure is on,
"P*"
shows in display. If pressure is off, "P_"
shows in display. If controls senses a problem with the pressure
output,
"P*"
shows in display, with the
Press
to view the "amps" status of each output.
"H
/"
and
"P
/"
in the display means the amps are good. A fl ashing
\
\
"X"
behind the H or P means a problem exists.
Press
to view the no connect/ground ("NC/GD") status of each
output. This monitors a possible problem with the relays on the
output PC board.
"H
/"
and
"P
/"
in the display means everything on output PC board
\
\
is good. A fl ashing
"X"
Press
to view the outputs and inputs (see step 10) together.
Press
to continue onto the POT TMP reading.
12. POT TMP
This step shows the present peanut oil temperature. The display
shows
"12. POT TMP (temp.)".
Press
to continue onto the CPU TMP reading.
13. CPU TMP
This step shows the present PC board temperature.
Press
to continue onto the ANALOG reading.
"*"
fl ashing.
"*"
fl ashing.
behind H or P means a problem exists.
Model 500/600
"_"
is displayed.
"H_"
shows in
"H*"
305