1-6. INFORMATION MODE
DETAILS
305
14. ANALOG <1> 2344
This step displays the present status of any channel of the
controller's a to d converter. This feature may be useful to a
technician troubleshooting a problem with the fryer or controller.
Displayed value can be toggled between volts and bits by pressing
. If the displayed value has a decimal point, it is voltage
(0 to 5 VDC). If no decimal point is shown, the value is a-to-d bits
(0 - 4095).
Press
to continue onto AC volts reading.

15. AC VOLTS 98%

This item displays the present status of the line voltage supply to
the fryer. The displayed value is averaged over a 10-second pe-
riod, so brief dips or fl uctuations in the voltage might not show up
in this display.
The voltage is normally displayed as a "percent of nominal" value,
where 100% would indicate that voltage is right on the nominal
value (i.e. 208 volts for a 208v fryer). The display can be toggled
to an actual Voltage value by pressing
Press
to continue onto AMPS reading.

16. AMPS 33 33 33

For electric fryers, this display shows the present readings from the
fryer's amps sensors, which monitor the electrical current supplied
to the heaters. (These sensors are not present on gas fryers.)
On pressure fryers, these values indicate the current through each
supply leg to the heaters. These values do not correspond directly
to the current through an individual heater coil.
The amps values should normally cycle on and off with the heat
light, and all three values should be about the same.
Press and hold
time, or after 2 minutes, controls automatically exit back
to normal operation.
Model 500/600
.
to exit Information Mode at any
1-41