Cook/Pump Switch; Continuity Check Procedure - Henny Penny 500 Technical Manual

Cfa pressure fryer electric/gas
Hide thumbs Also See for 500:
Table of Contents

Advertisement

2-13. ELECTRICAL
COMPONENTS
(Continued)
305

Cook/Pump Switch

(all models)
The Cook/Pump switch is a three way switch with a center
OFF position. With the switch in the COOK position the fryer
will operate. With the switch in the PUMP position the fi lter
pump will operate but the heating unit will not.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.

Continuity Check Procedure

1. Remove control panel.
2. Label and remove wires from the switch.
3. OFF position-should be open circuit anywhere on switch.
4. COOK position. Check from:
5. Pump position. Check from:
Replacement
1. Remove control panel per Replacing Control Panel Section.
2. Label wires at Cook/Pump switch and disconnect wires at
switch.
3. Remove faulty switch by pressing in on tabs on the switch,
behind the control panel and pull the switch through the
front of the panel.
Step 3
4. Install new switch.
5. Reconnect wires to switch in same position as noted on
labels.
6. Replace control.
Model 500/600
#5 to #6 closed circuit
#l to #2 closed circuit
#4 to #5 closed circuit
#3 to #2 closed circuit