2-14
Replacement
If either contactor is defective it must be replaced as follows:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove only those wires directly connected to the
contactor being replaced. Label the wires.
2. On the mercury heat contactor, use a 5/16" socket or nut-
driver and loosen four nuts securing contactor to shroud.
Slide contactor up and then pull out through the slotted
holes in the base of the contactor.
Step 2
3. On the primary contactor, remove two mounting screws on
the base plate and remove contactor.
4. Install the new contactor and tighten the two mounting
screws.
5. Connect the labeled wires to their respective positions.
6. Install the control panel.
7. Reconnect power to the fryer and test the fryer for
proper operation.