2-12. GAS CONTROL
VALVE (Continued)
Gasket
Operator
Spring
Interior Screw Cap
Exterior Screw Cap
305
Operator Replacement (continued)
4. Using a T20 "star" screwdriver, remove 4 screws securing
the operator and gasket.
5. Secure the new operator and gasket with the four screws
provided.
6. Reconnect the gas control valve wires.
7. Install the control panel per paragraph 2-4.
Step 5
Check Procedures:
120 volt - 50/60 Hz ..............2350 ohms
208-240 volt - 50/60 Hz
24 volt - 50/60 Hz ...................7 ohms

Regulator Spring Replacement

1. Remove the screw cap to the regulator.
2. Remove the plastic interior screw cap and spring.
3. Use gas control valve manufacturer's instructions from the
envelope containing the regulator spring, and follow the
directions.
Model 500/600
880 ohms
2-21