Safety Precautions; Electrical Components - Henny Penny 500 Technical Manual

Cfa pressure fryer electric/gas
Hide thumbs Also See for 500:
Table of Contents

Advertisement

2-13. ELECTRICAL
COMPONENTS
FAN
305

Safety Precautions

Do not disconnect the ground (Earth) plug. This fryer MUST
be adequately and safely grounded (Earthed) or electrical
shock could result. Refer to local electrical codes for cor rect
grounding (Earthing) procedures or in absence of local codes,
with The National Electrical Code, ANSI/NFPA No. 70-(the
current edition). In Canada, all electrical connections are to be
made in accordance with CSA C22.1, Canadian Electrical Code
Part 1, and/or local codes.
Electric motor bearings are permanently lubricated and do not
require attention during the normal service life of this fryer.
Fan (Gas Models)
The gas model fryers have a fan in the circuit. This fan operates
only with the Main Power switch in the ON position. The
fan helps keep the control panel cool by pulling out heat, from
between the control panel and frypot.
The replacement of a faulty fan is accomplished using following
procedure:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove control panel per Removing Control Panel section.
2. Label and disconnect fan motor wires.
3. Remove the four cap screws, washers and nuts securing the
fan to the heat shield.
4. Remove the fan from the heat shield.
5. Install the new fan on the heat shield and secure with the
four screws, washers, and nuts.
6. Reconnect the fan motor wires.
7. Install control panel per Removing Control Panel section.
Model 500/600
2-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

600

Table of Contents