2-7. HIGH TEMPERATURE
LIMIT CONTROL
(ELECTRIC AND
GAS MODELS)
(Continued)
CENTER
2-8
Electric
12. Carefully bend capillary bulb and tube toward bulb holders
on heating elements on electric units, and toward the welded
clips on gas units.
Hang 2 high limit bulb holders, for capillary bulb of the 450
degree high limit (part no. 16738) from the center of the top
element. See photo at left.
Gas
13. Slip capillary bulb into 2 bulb holders located on heating
elements, on electric units, and snap bulb in place in welded
clips, on gas units. Pull excess capillary line from pot and
tighten nut into frypot wall.
Be sure capillary bulb of high limit on electric units is not
located past the front of the elements. The capillary bulb
Step 13
and bulb holders should be positioned as not to interfere with
basket or when cleaning the frypot wall, or damage to capil-
lary tube could result.
14. With excess capillary line pulled out, tighten smaller nut.
15. Replace front panel.
16. Refi ll with shortening.