Henny Penny 500 Technical Manual page 59

Cfa pressure fryer electric/gas
Hide thumbs Also See for 500:
Table of Contents

Advertisement

2-9. HEATING
CONTACTORS
(ELECTRIC MODELS)
(Continued)
Heat Contactor
30 31 32
34 35
36
305
Checkout (power suppled)
To avoid electrical shock, make connections before apply-
ing power, take reading, and remove power before remov-
ing meter leads. The following checks are performed with
the wall circuit breaker closed and the main power switch
in the ON position.
1. With power re-applied, press one of product buttons to start
the unit heating.
2. On fryers using single phase power, check voltage as
follows:
Test Points
from pin D on
circuit breaker to:
terminal 34
terminal 35
terminal 36
(If voltage is not
present, check out-
put of primary
contactor at
terminals 27, 28,
and 29.)
3. On fryers using three-phase power, check voltage
as follows:
Test Points
Heat contactor
from terminal 34 to 35
from terminal 35 to 36
from terminal 34 to 36
Primary contactor
from terminal 27 to 28
from terminal 28 to 29
from terminal 27 to 29
Model 500/600
Results
The voltage
should read
the same at
each terminal.
It should
correspond to
the voltage
rating stated
on the data
plate.
Results
The voltage
should read
the same at
each terminal.
It should
correspond to
the voltage
rating stated
on the data
plate.
2-13