1-5. DIAGNOSTIC MODE
DETAILS (Continued)
305
D 3: Line Voltage Performance Report
This section displays information about how good the line voltage
supply has been for the present day and for the present batch of oil.
The controller continually monitors the line voltage supplied to the
fryer (when the fryer is on). If the line voltage drops below [90%]
of its nominal value, the controller signals a
alarm. This alarm sounds at the end of each Cook Cycle for which
low voltage has been detected. While not cooking, the low voltage
alarm can sound as frequently as every 30 minutes.
"[ ]"
around a value, such as [90%], means this value
is programmable and might change with later software
versions.

Voltage Report for Today

If no low voltage warnings have been detected for the present day,
the controller shows,
"D3: VOLTAGE OK, D3: TODAY "
If one or more low voltage warnings have been detected for the
present day, the following sequence example could be displayed:
D3: YOU HAD 3"
"
"D3: LOW VOLTAGE"
"D3: WARNINGS"
"D3: TODAY"
(Press
)
"D3: MIN VOLTAGE"
"D3: TODAY = 83%"
(Press
)
"D3: MAX VOLTAGE"
"D3: TODAY = 101%"
(Press
)
Model 500/600
"LOW VOLTAGE"
1-19