4) Wear limits
Description
Oil pump
Clearance main
pump (pump cover/
OP01
rotor)
Clearance suction
pump (pump cover /
OP01
rotor)
07204
Effectivity 912/914 Series
Edition 1 / Rev. 0
BRP-Rotax
Maintenance Manual
07429
wear
Reading new
limit
min
max
100%
0,00
0,05
0,20
0,0000
0,0020
0,0079
0,00
0,05
0,20
0,0000
0,0020
0,0079
0
90
10
80
20
70
30
1
0
9
0.01mm
2
8
3
7
4 5 6
60
40
50
wear
limit
50%
actual
0,13
0,0049
renewed
actual
0,13
0,0049
renewed
Readings
79-00-00
page 29
May 01/2007