3.2)
Electric starter — disassembly
3.2.1)
Fig. 80-3
19
22
21
Effectivity 912/914 Series
Edition 1 / Rev. 0
BRP-Rotax
Maintenance Manual
Standard starter
See Fig. 80-3
Unscrew combined nut (23) and remove connector sheath (17) with O-
ring (19). Pull bearing flange (1) off the starter housing (2). Carefully pull
rotor bearing (3) a short way off the starter housing and press the
positive carbon brush (23) with the connector sheath (17) out of the
rotor bearing.
Remove brush holder (4) with the carbon brushes from the rotor (5).
Pull rotor out of the starter housing together with compensating shim
(6) . Clean all parts thoroughly. See 00-00-00 sec. 10.3.
1
20
14
2
00231
5
11
12
10
18
15
6
19
13
17
23
4
14
80-00-00
May 01/2007
23
17
3
page 7