The bearings are tested by means of the pressure drop measuring
method.
■ CAUTION:
For this test, compressed air at approx. 2 bar (29 p.s.i)
and a testing device are needed.
Consisting of:
2
pressure gauges
1
orifice jet (inner diameter = 1 mm (.039 in.) / length = 3 mm
(.12 in.)
1
connecting nipple M12x1.5
for the thread in the middle section of the turbocharger
1
cover plate for the oil outlet
n.B. connecting hoses
Procedure:
Screw in the connecting nipple and close the oil outlet with the cover
plate.
Connect the pressure gauges together with the regulating valves.
Apply a constant pressure of 2 bar (29 p.s.i) to the connection
cable. The pressure drop must not exceed 50%.
(From 2 bar (29 p.s.i) to max. 1 bar (14.5 p.s.i))
◆ NOTE:
For optimum results, the position of the shaft should
always be changed slightly during the check, i.e. the
shaft should be moved backwards and forwards in axial
and radial directions.