adapter flange
potentiometer
Effectivity 914 Series
Edition 1 / Rev. 0
BRP-Rotax
Maintenance Manual
older model version part no. 861930
2
Fig. 76-36
older model version part no. 866480
Fig. 76-37
◆ NOTE:
- Inspection for physical damage.
- Measurement of the nominal resistance:
Measure resistance between connections (5) and (7).
Nominal resistance: 3.2 to 4.8 k
- Measurement of resistance across turning range of fitted
throttle.
To check the function of the throttle potentiometer over the
operating range, take the following readings:
newer model version part no. 861931
cut off edge
newer model version part no. 866481
distinguishing feature
Small installation tolerances can be compen-
sated by turning the throttle potentiometer.
For tolerances, see 76-00-00 sec. 3.1.1.6,
otherwise, recalibration is necessary.
05378
1
05379
76-00-00
page 39
May 01/2007