3.7)

Generator coils

See Fig. 74-12.
If the generator does not work, the reason may be a defective or damaged yellow
alternator cable or a defective winding on the 8 alternator coils (3). Disconnect
alternator cables (yellow) and check resistance values.
NOTE:
CAUTION : When performing any of the work described here, ensure that
Measure the resistance with a multimeter. See 74-00-00 sec. 3.12 and
74-00-00 sec. 5.
Effectivity 912/914 Series
Edition 1 / Rev. 0
BRP-Rotax
Maintenance Manual
If the value measured corresponds with the values specified, the
cause may be a defective rectifier-regulator.