Settings Options For Relay 9/J71 - Wexiodisk WD-6 Installation And User Manual

Hood type dishwasher
Table of Contents

Advertisement

Installation

3.6.2 Settings options for relay 9/J71

The function of relay 9/J71 can only be influenced by the reference value on row
22.
Relay 9/J71. Set/change the dosage interval during filling and
final rinse
1.
2.
3.
4.
5.
6.
7.
8.
Relay 9/J71. Constant voltage when the machine is started
1.
2.
3.
4.
5.
6.
7.
Relay 9/J71. Parallel operation with the chemical pump
1.
2.
3.
4.
5.
6.
7.
WD-6
Switch on the power to the machine.
Go into S1 mode, by pressing the service button on the data card.
Go to row 22.
Increase the setting by pressing "P2".
Reduce the setting by pressing "P3".
Leave S1 mode by pressing the 0/1 button.
The setting is saved when you leave S1 mode.
The new value will be used next time the machine is filled or after the next
final rinse, when the chemical wash start.
Switch on the power to the machine.
Go into S1 mode, by pressing the service button on the data card.
Go to row 22.
Change the setting to "00".
Leave S1 mode by pressing the 0/1 button.
The setting is saved when you leave S1 mode.
The new value will be used as soon as it is applicable.
Switch on the power to the machine.
Go into S1 mode, by pressing the service button on the data card.
Go to row 22.
Change the setting to "99".
Leave S1 mode by pressing the 0/1 button.
The setting is saved when you leave S1 mode.
The new value will be used as soon as it is applicable.
23
Rev. 4,0 (201302)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents